Year : 2018  |  Volume : 23  |  Issue : 2  |  Page : 87-89
 

Bronchoscopic airway foreign body extraction without using optical forceps


Department of Pediatric Surgery, Post Graduate Institute of Medical Education and Research, Chandigarh, India

Date of Web Publication29-Mar-2018

Correspondence Address:
Ravi Prakash Kanojia
Block 3A Advanced Pediatric Center, Post Graduate Institute of Medical Education and Research, Sector 12 Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jiaps.JIAPS_85_17

Rights and Permissions

 

   Abstract 


Aim: Airway foreign body (FB) is a very common pediatric surgical emergency. On certain difficult occasions, the extraction of FB with optical forceps (OFs) is difficult. These conditions create a life-threatening scenario. We present some of the alternative methods of FB extraction for these situations.
Patients and Methods: This is a retrospective case review of patients presenting to pediatric emergency with airway FB. All patients had a chest X-ray done before the procedure. Rigid bronchoscopy was performed in all patients for retrieval.
Results: A total of 20 patients (6 females) were successfully scoped. The age ranged from 1.5 years to 12 years (mean 3.5 years). Bronchoscopic removal was aided by dormia basket (DB) in 13, Fogarty's catheter (FC) in 6, and magnet aided removal in 1. Complete removal was achieved in all patients.
Conclusions: We recommend that DB, FC, and a magnet should form an indispensable part of bronchoscopy set. The use of these alternative methods is successful and allows ventilation during the removal in contrast to removal by OFs. These should be kept as an option if retrieval is difficult.


Keywords: Airway foreign body, bronchoscopy, endoscopic, pediatric


How to cite this article:
Hegde S, Bahadur U, Kanojia RP, Bawa M, Samujh R. Bronchoscopic airway foreign body extraction without using optical forceps. J Indian Assoc Pediatr Surg 2018;23:87-9

How to cite this URL:
Hegde S, Bahadur U, Kanojia RP, Bawa M, Samujh R. Bronchoscopic airway foreign body extraction without using optical forceps. J Indian Assoc Pediatr Surg [serial online] 2018 [cited 2019 Sep 15];23:87-9. Available from: http://www.jiaps.com/text.asp?2018/23/2/87/228898





   Introduction Top


Airway foreign bodies (FB) are one of the most common pediatric surgical emergencies. The condition poses a life-threatening risk if not treated in time.[1] Rigid bronchoscopy is the procedure of choice and the optical forceps (OF) available are capable of successfully retrieving the FB in the majority of cases. There are certain situations when retrieval by the available OF is difficult. These can be due to an impacted FB, smooth surface metallic objects such as lead pellets, glass beads, and distally migrated FB out of reach of OF. These circumstances pose a very desperate life-threatening situation, and the surgeon has to innovate on the spot to resolve the situation successfully. We present alternative methods of FB retrieval when the removal by OF fails, and the situation demands an immediate solution. The following case series presented involves removals of airway FB by alternative methods either due to OF failure or as a testing method under controlled situation. Recent available literature is also reviewed.


   Patients and Methods Top


This case series was a retrospective case review done for all patients who were admitted for airway FB from 2015 to 16. During this 2-year period, a total of 48 patients were admitted with foreign body (FB) aspiration and underwent bronchoscopy. These patients were admitted at emergency, and a chest X-ray was the only investigation done. Contrast CT was done if indicated for long-standing FB. The timing of bronchoscopy depended on the clinical situation of the child and varied from an hour to the next morning. The alternate procedures used were retrieval by dormia basket (DB), Fogarty's catheter (FC), and magnet aided removal. The DB used was a 3.5 fr, 4 cm, and 3 loop/prong basket with length 45 cm. The basket was passed beyond the FB and opened and gently withdrawn to trap the FB. Once the FB was inside the basket it was closed to have a soft but snug grip [Figure 1]. The entire scope with the basket was then removed to retrieve the FB. FC was used for disimpaction and safely dragging the FB in the trachea. Magnet aided removal was done with an outside placed magnet on the extended neck. This is described later. The choice of method of removal without OF was based on the difficulty in the removal and was decided by the surgeon on case by case basis.
Figure 1: Foreign body trapped in dormia and ready to be pulled out

Click here to view



   Results Top


Totally 20 patients (6 females) were successfully scoped by the non-OFs method. The age ranged from 1.5 years to 12 years (mean 3.5 years). Three patients underwent CECT chest for diagnosis of longstanding airway FB. Five patients had a history of unsuccessful attempt at bronchoscopic retrieval done outside our hospital.

The removal was aided by DB in 13, FC in 6, and magnet aided removal in 1. FC used in some scenarios is described. First one being impacted FB where holding the FB with OF makes it either slip away and gets further impacted like a cork in a bottle. The FC tip was made to pass beyond the FB, and the balloon was inflated, and the catheter was gently withdrawn. The bulb of the FG then pushes the FB from behind (push rather than pull) dis-impacting it from the narrow airway and then pushing it toward the main stem from where it is retrieved safely by OF. In the second case, FC was used in a perforated glass bead where the bead was a part of a necklace. FG was made to pass through the central hole of the bead, and then the balloon was inflated to lock the beat with the FC and retrieved. The nature of FB retrieved was nuts and vegetables in 13, metallic and toy parts in 6, and a large magnet in complete removal was achieved in all patients.


   Discussion Top


The pediatric surgery emergency has a regular input of patients with FB bronchus. The patient is usually a curious toddler who tends to pick and chew on small objects while playing. It has been reported that 75.4% of aspiration cases occur in children less than 3 years old with a predilection to males.[1] Complications such as persistent cough, pneumonia, and bronchiectasis are more common if the diagnosis is made a month after aspiration.[2] Mortality is also reported due to an FB aspiration.[3]

Rigid bronchoscopy remains the gold standard for the removal of FB from the tracheobronchial tree under direct vision.[4],[5] The availability of good quality OF has increased the success in bronchoscopic retrieval, but it has its own limitations. Inability to ventilate during the passage of the instrument and reduced vision in terms of optical quality are some limitations, in addition to what has been mentioned earlier. There are conditions when the surgeon needs some other resource for emergency rescue.

The study outlines the use of DB, FC and magnet as alternative method of FB retrieval when OF fails to do so and creates a desperate life-threatening situation. DBs have been used rarely to extract FB bronchus. There have been 4 previously published reports of isolated cases, the earliest being in 1971.[6],[7],[8],[9] 13 of our patients were successfully treated using a DB which is the largest series of patients in the pediatric population till date. Complications include mucosal trauma and pneumothorax due to forceful insertion of basket. In our patients, no complications happened.

FC was first used to extract FB bronchus in 1968. It has also been used in the removal of FB from the esophagus,[10] urethra,[11] and nose.[12] We have used FC in 6 of our patients. We encountered no complications in any of our cases. A retrospective analysis of 26 pediatric FB removed with bronchoscopic FC by Chen et al. concludes it to be a safe, effective, and easily performed method.[13] Risks of using FC include catheter disruption, tip dislodgement, and airway damage.

An interesting case was of an 8-year-old boy who had swallowed a large magnet which was impacted in his right main bronchus. There was a previous failed attempt at bronchoscopic removal before referral. On bronchoscopy, the magnet was impacted like a cork in a bottle, and its smooth wall was not amenable to be held by OF. Situations like the one above compel the surgeon to be creative and resourceful. A magnet was used externally on the chest wall [Figure 2]. The FB within continued to be under bronchoscopic vision, and it could be seen walking along the bronchus without any assistance from an instrument within. At the laryngeal inlet, it was extracted by a Magill's forceps. The use of a magnet to remove an FB was first reported way back in 1904 by way of a tracheotomy.[14]
Figure 2: Magnet aided retrieval with external magnet

Click here to view


With the given experience we recommend that the FC DB and magnet should form an indispensable part of bronchoscopy set. The use of these alternative methods is successful and allows ventilation during the removal in contrast to removal by OF. These should be kept as an option if retrieval is difficult.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Mnejja M, Chakroun A, Bougacha L, Smaoui L, Ben Salah M, Chakroun A, et al. Bronchoscopy for foreign body inhalation in the pediatric population: Lessons learned from 223 cases. Arch Pediatr 2012;19:670-4.  Back to cited text no. 1
[PUBMED]    
2.
Karakoç F, Karadaǧ B, Akbenlioǧlu C, Ersu R, Yildizeli B, Yüksel M, et al. Foreign body aspiration: What is the outcome? Pediatr Pulmonol 2002;34:30-6.  Back to cited text no. 2
    
3.
Oǧuzkaya F, Akçali Y, Kahraman C, Bilgin M, Sahin A. Tracheobronchial foreign body aspirations in childhood: A 10-year experience. Eur J Cardiothorac Surg 1998;14:388-92.  Back to cited text no. 3
    
4.
Basu A, Basu J. Foreign bodies in the air passage of children. J Indian Assoc Pediatr Surg 1996;1:23-8.  Back to cited text no. 4
  [Full text]  
5.
Korlacki W, Korecka K, Dzielicki J. Foreign body aspiration in children: Diagnostic and therapeutic role of bronchoscopy. Pediatr Surg Int 2011;27:833-7.  Back to cited text no. 5
[PUBMED]    
6.
Awad Z, Pothier DD. A potential danger of flexible endoscopy sheaths: A detached tip and how to retrieve it. J Laryngol Otol 2009;123:243-4.  Back to cited text no. 6
[PUBMED]    
7.
Dajani AM. Bronchial foreign-body removed with a Dormia basket. Lancet 1971;1:1076-7.  Back to cited text no. 7
[PUBMED]    
8.
Nandalike K, Kessel A, Tripathi S, Sweberg T, Vicencio AG. Foreign body aspiration in a child with unilateral lung aplasia. Pediatr Crit Care Med 2011;12:e216-8.  Back to cited text no. 8
[PUBMED]    
9.
Varshney R, Zawawi F, Shapiro A, Lacroix Y. Use of an endoscopic urology basket to remove bronchial foreign body in the pediatric population. Int J Pediatr Otorhinolaryngol 2014;78:687-9.  Back to cited text no. 9
[PUBMED]    
10.
Lemberg PS, Darrow DH, Holinger LD. Aerodigestive tract foreign bodies in the older child and adolescent. Ann Otol Rhinol Laryngol 1996;105:267-71.  Back to cited text no. 10
[PUBMED]    
11.
Fox JR. Fogarty catheter removal of nasal foreign bodies. Ann Emerg Med 1980;9:37-8.  Back to cited text no. 11
[PUBMED]    
12.
Cumes DM. Use of Fogarty balloon catheter in removal of smooth foreign bodies from male urethra. Urology 1979;13:300.  Back to cited text no. 12
[PUBMED]    
13.
Chen X, Chen Y, Zhong C, Zeng Y, Luo W, Li S, et al. The efficacy and safety of airway foreign body removal by balloon catheter via flexible bronchoscope in children – A retrospective analysis. Int J Pediatr Otorhinolaryngol 2016;82:88-91.  Back to cited text no. 13
    
14.
Hosmer AJ. V. On the use of an electro-magnet for removal of a foreign body from a bronchus. Ann Surg 1904;40:350-3.  Back to cited text no. 14
[PUBMED]    


    Figures

  [Figure 1], [Figure 2]



 

Top
Print this article  Email this article

    

 
  Search
 
  
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (712 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Patients and Methods
   Results
   Discussion
    References
    Article Figures

 Article Access Statistics
    Viewed1147    
    Printed63    
    Emailed0    
    PDF Downloaded75    
    Comments [Add]    

Recommend this journal


Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer 

  2005 - Journal of Indian Association of Pediatric Surgeons | Published by Wolters Kluwer - Medknow 

Online since 1st May '05